How To Replace the TOUGH GUN CA3 Gun Unicable

IMPORTANT: The following instructions pertain to unicable replacement on TOUGH GUN CA3 MIG Guns manufactured on or after April 8, 2015 NOTE: Unicable replacement can be done while the gun is mounted to the robot. There is no need to uninstall the gun before proceeding. Remove nozzle, retaining head and liner.FOR CLUTCH MODELS ONLY: Disconnect […]

read more...

How To Install the TOUGH GUN TT3 Reamer Sprayer Valve Retrofit Kit

Required Tools: 9/16″ wrench11/16″ wrench5 mm Allen key3 mm Allen key2.5 mm Allen keyPrecision flat head screwdriverWire strippers Installation Instructions Disconnect power and air. Identify your anti-spatter source (bulk-feed or Tregaskiss supplied reservoir). Disconnect the source from the bracket mounted on the side of your TOUGH GUN® TT3 Reamer. Remove the MALE fitting from the […]

read more...

How To Add the Lubricator to the TOUGH GUN TT3 Reamer

WARNING: Ensure the power and air supplies to the TOUGH GUN® Reamer are disconnected or disabled prior to working with the Reamer.  ItemDescriptionPart NumberQty15/16″ x 1/18″ NPT QCTR-223122Bulkhead AdaptorLR-500-5123SpacerLR-500-50-514M6x1x20mm LG SHCS – Black OxideF1-M6X1-20B25Steel Line Kit – For LubricatorLR-500-5016Lubricator TT-LUB-SMC1 1. Remove lubricator kit from the box and inspect for any damage. 2. Remove the reservoir […]

read more...

How To Remove and Install Wire Brake in a TOUGH GUN ThruArm Series MIG Gun

NOTICE: This product is factory set for wire equal to or smaller than 0.045“. If you are using wire 0.052” and larger, please remove the wire guide within the neck housing and replace it with the larger size (part #598-116) that is supplied in the box with this product. Removal and Installation Instructions Follow the […]

read more...

How To Install Air Blast on TOUGH GUN G1 Series Robotic MIG Guns

AIR BLAST KIT 508-A (does not include housing)  Remove 408-200-9A using a standard screwdriver Remove 408-200-8A using a standard screwdriver Thread 410-45-2 into 408-200-8A using xx wrench Insert TR-2237 into push-lock connections of TR-2232 and 410-45-2. Insert TR-2232 into air supply, 60-80 psi air pressure 408-200-9A 408-200-8A (internal threads) 410-45-2

read more...

How To Mount the RS-500 Sprayer as a Stand-Alone Unit

The sprayer should be installed within the weld cell at a convenient location. Be sure to consider movable fixtures and the confines of the robot. Each sprayer comes complete with all required installation hardware and mounting brackets.

read more...

How To Mount the SR-500 Sprayer to the TOUGH GUN Reamer

The TOUGH GUN­® Reamer has all the necessary mounting holes for installation of the SR-500 spray unit. Remove the plug from the side of the frame detail and replace with the supplied bulkhead fitting.Attach the spray head bracket to the TOUGH GUN Reamer using the two (2) screws provided.Attach the spray head to the TOUGH […]

read more...

How To Install the TOUGH GUN Wire Cutter to the TOUGH GUN Reamer

WARNING: Ensure the power supply is off and disconnected before proceeding! Mounting the Wire Cutter The Wire Cutter should be installed within the weld cell. The base plate has been designed for mounting on top of the TOUGH GUN™ Reamer. Be sure to consider movable fixtures and the confines of the robot. Attach the Wire Cutter […]

read more...

How To Install the TOUGH GARD Multi-Feed System to the TOUGH GUN Reamer

Step 1: It is best to start by establishing the pail/drum location. This way it will be easier to run the lines and permanently secure them.Start by removing the reservoir from the spray unit.NOTE: Shut the vent cap (if applicable) and turn the reservoir upside down when it comes off the spray unit to avoid […]

read more...

How To Install the TOUGH GUN Reamer TT Series

WARNING: Ensure the power supply is off and disconnected before proceeding! Mounting the TOUGH GUN® Reamer The TOUGH GUN Reamer should be installed within the weld cell at a convenient location. Be sure to consider movable fixtures and the working envelope of the robot.Affix the TOUGH GUN Reamer base to a sturdy platform using the four […]

read more...

How To Install or Replace a Neck on a TOUGH GUN G2 Series Robotic MIG Gun

Neck Removal Remove consumables. (Refer to Fig.1)Twist the hand nut clockwise. (Refer to Fig. 2)Hold the hand nut in the unlocked position while pulling the neck from the gun.Release the hand nut. It will return to the locked position. (Refer to Fig. 3) Neck Replacement NOTE: Remove consumables (retaining head, nozzle and contact tip) before installing […]

read more...

How To Use the TOUGH GUN Neck Checking Fixture

NOTE: The following instructions are for G-405. Other fixtures are similar. Step 1: Remove consumables; nozzle, retaining head and neck insulator (with the exception of TOUGH GUN I.C.E.® components).Install the gauge point into the neck. Step 2: Slide the neck completely into the datum block, aligning keys on the neck to the keyway in the […]

read more...

How To Install or Replace a Neck on TOUGH GUN G1 Series Guns

NOTE: There is a protective ring that must be rotated to expose the neck set screw.  Step 1: Using a 5 mm Allen wrench, loosen the screw 1/4 turn to remove the neck.Pull the neck directly out of the connector cone assembly. Step 2:  Insert the replacement neck into the gun housing, ensuring the key […]