How To Install Front-End Air Blast for TOUGH GUN ThruArm Series MIG Guns
Step 1:
- Remove the 2 screws which retain Item #1 and slide cover back to expose Item #2.
- Locate Items #2 and #3 and remove both pieces.
- Once Items #2 and #3 have been removed, remove Item #4 from the front housing by loosening the pinch bolt through clearance hole in aluminum spacer.
Step 2:
- Install Items #6 and #7 where Item #3 was removed.
- Feed Item #5 through the exposed hole in the front of the housing and through the outer cover of Item #4 as shown below.
- Feed tubing through until there is only enough tube remaining to connect Item #7.
- Reinstall Item #4 into the front housing by tightening the pinch bolt through clearance hole in aluminum spacer.
- The tube will need to be pulled out of the rear of Item #4 and connected to the compressed air source.
Note: Items #5, #6 and #7 above are components of Air Blast Kit Part #560-500FA.
INS092 07/13