Product Guide: Clean Air E™ – Changing the Y Connector
Keep your Bernard® Clean Air E™ Fume Extraction MIG Gun performing at its best by replacing the Y-connector when needed. This quick guide walks you through the simple steps to ensure a secure fit and maintain optimal fume extraction efficiency. Watch now to keep your system running smoothly and your workspace cleaner.
Instructions
Separate connector halves.
Push rear hose swivel forward to slide it out of the cavity. Slide the hose assembly forward and remove the remaining Y Connector half.
Place the new rubber boot into the new Y Connector set.
Position the cable assembly in the Y Connector channel, ensuring proper alignment with rubber boot.
Pull the hose assembly back into the swivel cavity and ensure it is taut (no slack).
Confirm the hose and cable assemblies are properly seated and secure.
Align the Y Connector halves and reinstall screws.
Find more resources at www.startsatthesource.com